NEXO PS15-TDController-R2 Analogue TDcontroller
PS15 TDController advanced analogue processor allows the PS15 Loudspeaker and optional PS15Bass and LS1200 Subwoofers to achieve exceptional performance from such compact packages.

The PS15 TDController provides crossover, sensed amplifier control and system equalisation optimised for the PS15, PS15Bass and LS1200. The PS15 TD MkII also features user- selectable passive or active (bi-amp) operation of the PS15 Loudspeaker. OneTDController has two inputs and three outputs, including summed sub out, minimising installation cost and complexity.
Like all NEXO processors, the PS15 TDController provides precision dynamic, voice coil temperature and diaphragm displacement protection through the use of selective Voltage Controlled Equalisers (VCEQs), reducing levels only at frequencies when and where necessary.
Features
| Connectors | Two XLR-3F connectors (differential non floating L&R audio inputs, 50 kΩ) |
| Sense Inputs: | 6 Pole Removable Strip Terminal (three amplifier sense inputs - Left, Right and Sub - 400 kΩ) |
| Audio Outputs: | Two XLR-3M connectors (balanced non floating L&R audio outputs, 51Ω) One XLR-3M connector (balanced non floating Sub audio outputs, 51Ω) |
| Controls: | Gain switch (back panel), 3 positions : -6 / 0 /+6dB. Peak Limiter trimmer for PS & Sub. Sub Overlap / Crossover switch & Sub Gain Control (-/+ 6dB) |
| Indicators: | LF speakers Protect Yellow LED's (Temp. & Disp), Power ON (green), Amp Sense & Peak LEDs (green/Red) |
Specifications
| Output Section: | +22 /+16/+10 dBm typical into 600 Ω load (+6/0/-6dB back panel switch) |
| Input Section: | Maximum input level: 22dBu. CMRR 80dB @ 1kHz typical |
| THD+N: | 0.1% @ 1kHz Typ. for +10dBm output |
| Noisefloor: | PSTD -100 dBv for 0dB switch position (22 Hz - 22 kHz, unweighted) |
| Dynamic Range: | 111 dB unweighted (THD+N at-60dBr sine wave @1kHz relative to maximum output) |
| Crosstalk: | 104dB |
| Filtering & EQ: | L&R: 12dB/ oct Low Pass, 12dB/oct High pass (crossover or overlap), 4 Parameter EQs. Factory defined |
| Protections: | VCA temp. (SUB,LF & LF), VCEQ disp. (SUB & LF), Peak Limiter (all chanels), Power compression regulation |
| Power Supply: | 100-250 Volts (continuous operation), 50/60Hz. Power 9W. Peak inrush current 0.5A. Earth-Lift |
| Conformity: | Comply with safety objective of 73/23/EEC & 89/336/ EEC directives. (EN60065-12/2001, EN55103-1996). CB scheme DK-8371, cULus 60065 AZSQ E241312, FCC part15 class B |
| Dimensions: | 1RU 19" Rack. 165mm (6.5") Depth |
| Weight: | 2.9kg |
Tech Downloads
- Nexo PS R2 Series Manual, pdf Format (5.87 MB)
- Nexo PS Series Manual, pdf Format (1.28 MB)
- Nexo PS15 TDController Datasheet, pdf Format (167 KB)
Sales Brochures
- Nexo PS R2 Series Brochure, pdf Format (3.33 MB)
- Nexo PS Series Brochure, pdf Format (762 KB)
- Nexo PS15 Brochure, pdf Format (3.73 MB)
- Nexo PS15 TDController Brochure, pdf Format (334 KB)