GT AustralasiaSubscribe to Filter eMagazine
Group Technologies Group Technologies HomeProductsProfileDownloadsNewsPartners in ActionGT PartnersFilter NewsletterContact

Sommer Bulk Cables - Various - Tech Data & options - Mercator + P


TECHNICAL DATA:
Construction S/FTP4x2xAWG24+2x2,5mm 2
AWG 24
Conductor insulation PE 0,98 mm
Shielding copper braiding tin-plated 55 % + AL/PT-foil
Shielding factor 100 %
Temperature range min. -20 °C
max. 75 °C
Weight per 1 m 190 g
Packaging 100 mroll, per m
Capac. cond./cond. per 1 m (CAT.5) 47 pF
Insulation resist. per 1 km > 2 GOhm
Surge impedance (+/-15 %) 100 Ohm
Loop resistance max. 168 Ohm/m
Velocity factor 0,74
   
PRICING: Call Group Technologies for Sommer Cable price enquiries

CABLE OPTIONS

Jacket, diameter PVC 12,5 mm FRNC 11,0 mm
No. of conductors 4 x 2 x .14 mm 2 + 2 x 2.5 mm 2 ---
No. of inner conductors --- 4 x 2 x .020 inch + 2 x 2.5
Fire load per m 0,74 kWh 0,54 kWh
Color   grey   grey
Damping per 100 m (20 °C) 1 MHz: 2,5 dB 1 MHz: 1,9 dB
10 MHz: 8,4 dB 10 MHz: 6,0 dB
20 MHz: 12,5 dB 20 MHz: 8,6 dB
62 MHz: 23,6 dB 62 MHz: 15,5 dB
100 MHz: 29,9 dB 100 MHz: 20,0 dB
155 MHz: 37,4 dB 155 MHz: 26,2 dB
200 MHz: 42,8 dB 200 MHz: 29,5 dB
4 MHz: 5,2 dB 4 MHz: 3,8 dB
--- 31 MHz: 16,0 dB 31 MHz: 10,8 dB
Order No.
580-0156P 580-0156PF

Home | Products | Company Profile | Downloads | Nexo News | Nexo in Action | Nexo Hire Info | Contact